# HX711 Module This module provides access to an HX711 load cell amplifier/ADC. The HX711 is an inexpensive 24bit ADC with programmable 128x, 64x, and 32x gain. Currently only channel A at 128x gain is supported. Note: To save ROM image space, the hx711 module is not compiled into the firmware by default. ## hx711.init() Initialize io pins for hx711 clock and data. #### Syntax `hx711.init(clk,data)` #### Parameters - `clk` pin the hx711 clock signal is connected to. - `data` pin the hx711 data signal is connected to. #### Returns `nil` #### Example ```lua -- Initialize the hx711 with clk on pin 5 and data on pin 6 hx711.init(5,6) ``` ## hx711.read() Read digital loadcell ADC value. #### Syntax `hx711.read(mode)` #### Parameters - `mode` ADC mode. This parameter is currently ignored and reserved to ensure backward compatability if support for additional modes is added. Currently only channel A @ 128 gain is supported. |mode | channel | gain | |-----|---------|------| | 0 | A | 128 | #### Returns a number (24 bit signed ADC value extended to the machine int size.) #### Example ```lua -- Read ch A with 128 gain. raw_data = hx711.read(0) ```