nodemcu-firmware/docs/en/modules/hx711.md

1.5 KiB

HX711 Module

Since Origin / Contributor Maintainer Source
2015-10-09 Chris Takahashi Chris Takahashi hx711.c

This module provides access to an HX711 load cell amplifier/ADC. The HX711 is an inexpensive 24bit ADC with programmable 128x, 64x, and 32x gain. Currently only channel A at 128x gain is supported.

Note: To save ROM image space, this module is not compiled into the firmware by default.

hx711.init()

Initialize io pins for hx711 clock and data.

Syntax

hx711.init(clk, data)

Parameters

  • clk pin the hx711 clock signal is connected to
  • data pin the hx711 data signal is connected to

Returns

nil

Example

-- Initialize the hx711 with clk on pin 5 and data on pin 6
hx711.init(5,6)

hx711.read()

Read digital loadcell ADC value.

Syntax

hx711.read(mode)

Parameters

mode ADC mode. This parameter is currently ignored and reserved to ensure backward compatability if support for additional modes is added. Currently only channel A @ 128 gain is supported.

mode channel gain
0 A 128

Returns

a number (24 bit signed ADC value extended to the machine int size)

Example

-- Read ch A with 128 gain.
raw_data = hx711.read(0)