2.4 KiB
2.4 KiB
dht Module
Constants
dht.OK
(0), dht.ERROR_CHECKSUM
(1), dht.ERROR_TIMEOUT
(2)
dht.read()
Read all kinds of DHT sensors, including DHT11, 21, 22, 33, 44 humidity temperature combo sensor.
Syntax
dht.read(pin)
Parameters
pin
pin number of DHT sensor (can't be 0), type is number
Returns
status
as defined in Constantstemp
temperature (see note below)humi
humidity (see note below)temp_dec
temperature decimalhumi_dec
humidity decimal
!!! note "Note:"
If using float firmware then `temp` and `humi` are floating point numbers. On an integer firmware, the final values have to be concatenated from `temp` and `temp_dec` / `humi` and `hum_dec`.
Example
pin = 5
status, temp, humi, temp_dec, humi_dec = dht.read(pin)
if status == dht.OK then
-- Integer firmware using this example
print(string.format("DHT Temperature:%d.%03d;Humidity:%d.%03d\r\n",
math.floor(temp),
temp_dec,
math.floor(humi),
humi_dec
))
-- Float firmware using this example
print("DHT Temperature:"..temp..";".."Humidity:"..humi)
elseif status == dht.ERROR_CHECKSUM then
print( "DHT Checksum error." )
elseif status == dht.ERROR_TIMEOUT then
print( "DHT timed out." )
end
dht.read11()
Read DHT11 humidity temperature combo sensor.
Syntax
dht.read11(pin)
Parameters
pin
pin number of DHT11 sensor (can't be 0), type is number
Returns
status
as defined in Constantstemp
temperature (see note below)humi
humidity (see note below)temp_dec
temperature decimalhumi_dec
humidity decimal
!!! note "Note:"
If using float firmware then `temp` and `humi` are floating point numbers. On an integer firmware, the final values have to be concatenated from `temp` and `temp_dec` / `humi` and `hum_dec`.
See also
dht.readxx()
Read all kinds of DHT sensors, except DHT11.
####Syntax
dht.readxx(pin)
Parameters
pin
pin number of DHT sensor (can't be 0), type is number
Returns
status
as defined in Constantstemp
temperature (see note below)humi
humidity (see note below)temp_dec
temperature decimalhumi_dec
humidity decimal
!!! note "Note:"
If using float firmware then `temp` and `humi` are floating point numbers. On an integer firmware, the final values have to be concatenated from `temp` and `temp_dec` / `humi` and `hum_dec`.