# DHT Module
| Since | Origin / Contributor | Maintainer | Source |
| :----- | :-------------------- | :---------- | :------ |
| 2017-03-30 | [Arnim Läuger](https://github.com/devsaurus) | [Arnim Läuger](https://github.com/devsaurus) | [dht](../../components/modules/dht.c)|
## Constants
Constants for various functions.
`dht.OK`, `dht.ERROR_CHECKSUM`, `dht.ERROR_TIMEOUT` represent the potential values for the DHT read status
## dht.read11()
Read DHT11 humidity temperature combo sensor.
#### Syntax
`dht.read11(pin)`
#### Parameters
`pin` IO index, see [GPIO Overview](gpio.md#gpio-overview)
#### Returns
- `status` as defined in Constants
- `temp` temperature
- `humi` humidity
- `temp_dec` temperature decimal (always 0)
- `humi_dec` humidity decimal (always 0)
#### Example
```lua
pin = 4
status, temp, humi = dht.read11(pin)
if status == dht.OK then
print("DHT Temperature:"..temp..";".."Humidity:"..humi)
elseif status == dht.ERROR_CHECKSUM then
print( "DHT Checksum error." )
elseif status == dht.ERROR_TIMEOUT then
print( "DHT timed out." )
end
```
## dht.read2x()
Read DHT21/22/33/43 and AM2301/2302/2303 humidity temperature combo sensors.
#### Syntax
`dht.read2x(pin)`
#### Parameters
`pin` IO index, see [GPIO Overview](gpio.md#gpio-overview)
#### Returns
- `status` as defined in Constants
- `temp` temperature (see note below)
- `humi` humidity (see note below)
- `temp_dec` temperature decimal
- `humi_dec` humidity decimal
!!! note
If using float firmware then `temp` and `humi` are floating point numbers. On an integer firmware, the final values have to be concatenated from `temp` and `temp_dec` / `humi` and `hum_dec`.
#### Example
```lua
pin = 4
status, temp, humi, temp_dec, humi_dec = dht.read2x(pin)
if status == dht.OK then
-- Integer firmware using this example
print(string.format("DHT Temperature:%d.%03d;Humidity:%d.%03d\r\n",
math.floor(temp),
temp_dec,
math.floor(humi),
humi_dec
))
-- Float firmware using this example
print("DHT Temperature:"..temp..";".."Humidity:"..humi)
elseif status == dht.ERROR_CHECKSUM then
print( "DHT Checksum error." )
elseif status == dht.ERROR_TIMEOUT then
print( "DHT timed out." )
end
```